Comparison between Theoretical Calculation and STRUDS Result

Slab S1 - Comparison between Theoretical Calculation and STRUDS Result
________________________________________
Comparison between Theoretical Calculation and STRUDS result:

MidShort-Ast (Reqd in mm2) ,Theoretical- 154.4704, STRUDS -154.382, Deviation (%) 0.057

MidLong-Ast (Reqd in mm2) , Theoretical - 113.4108 STRUDS- 113.357, Deviation (%) 0.047

SuppDown -Ast (Reqd in mm2),Theoretical-0.000 ,STRUDS- 0.000, Deviation (%) 0.000

SuppTop -Ast (Reqd in mm2),Theoretical-0.000 ,STRUDS-0.000 ,Deviation (%) 0.000

SuppLeft -Ast (Reqd in mm2),Theoretical-0.000 ,STRUDS- 0.000, Deviation (%) 0.000

SuppRight- Ast (Reqd in mm2),Theoretical-208.6199, STRUDS-208.510 ,Deviation (%)0.053


Comparison of STRUDS Design with Theoretical Design for Beam B4'
________________________________________


Theoretical Ast Provided for Section1- 2-10 top,Section2 - 2-10 top,Section3 - 2-10 top ,Section4- 2-10 top,Section5- 2-10 top

Theoretical Ast Provided for Section1- 2-10 bottom,Section2- 2-10 bottom,Section3- 2-10 bottom,Section4- 2-10 bottom,Section5- 2-10 bottom

Ast Provided As per STRUDS for Section1- 2-10 top,Section2- 2-10 top,Section3- 2-10 top,Section4- 2-10,Section5- top 2-10 top
Ast Provided As per STRUDS for Section1- 2-10 bottom,Section2- 2-10 bottom,Section3- 2-10 bottom,Section4- 2-10 bottom,Section5- 2-10 bottom

Ast Deviation (%)between Theoretical and STRUDS for Section1- NIL ,Section2- NIL,Section3- NIL,Section4- NIL ,Section5- NIL

Comparison of STRUDS Design with Theoretical Column Design

Column size (mm) for Theoretical Results- 230 * 300, STRUDS Results- 230 * 300 Deviation (%)between Theoretical Results and STRUDS Results - NIL

Main Steel for Theoretical Results- 8 bars – 12 mm dia, STRUDS Results- 8 bars – 12 mm dia,Deviation (%)between Theoretical Results and STRUDS Results - NIL

Stirrups for Theoretical Results- 6 mm @190 mm c/c,STRUDS Results- 6 mm @ 190 mm c/c, Deviation (%)between Theoretical Results and STRUDS Results - NIL

Comparison of Theoretical Results with STRUDS Footing Design

Footing Length L in mm for Theoretical Results- 850, STRUDS Results- 850 0.00
Footing Width B in mm for Theoretical Results- 925,STRUDS Results- 925,Deviation (%)between Theoretical Results and STRUDS Results - 0.00
Footing Depth D in mm for Theoretical Results- 225,STRUDS Results- 225,Deviation (%)between Theoretical Results and STRUDS Results - 0.00
Ast Along X for Theoretical Results- 6 Bars of 8 mm Dia,STRUDS Results- 6 Bars of 8 mm Dia,Deviation (%)between Theoretical Results and STRUDS Results - 0.00
Ast Along Y for Theoretical Results- 6 Bars of 8 mm Dia,STRUDS Results- 6 Bars of 8 mm Dia,Deviation (%)between Theoretical Results and STRUDS Results - 0.00

Click here to see some of the best rcc softwares in india

Click here to see my blog on rcc softwares

Click here to see rcc manual

Click here to see my website on rcc softwares

Click here to see paying sites

Click here to join Indian paying survey

Click here to send sms on your mobile in india

Click here to earn money by recieving sms on your mobile in india

Click here to join inonlinesurvey.com

Click here to send free Sms to any mobile in india